CIS Only | DCVG Only | Combined CIS/DCVG

Package for both CIS and DCVG survey types

Current Interruption

A Current Interrupter is required for all survey types.
Please select a Current Interrupter:

Click here for more information about our interrupters.
How many interrupters do you require?

M.C. Miller Dataloggers

Which data-logger do you prefer?
Click for more information on our datalogger options: M.C.Miller Dataloggers

Use of the VADER requires an Android™ tablet (supplied by customer) and purchase of an associated applications (Test Site Survey and Pipeline Survey) , and will include the VM Lite app. VM Lite allows for basic collection of meter readings which can be downloaded into a spreadsheet program. Data collection for CIS surveys requires the Pipeline Survey (PLS) application which the wizard will add by default. You may also purchase the Test Site Survey application by checking the box below.

NOTE: Viewing and manipulating data gathered with the Test Site Survey application requires a data managment program such as ProActive. Checking this box will also add one copy of the Single-User ProActive application to your cart. If you require a version of ProActive that supports multiple users, please abandon this wizard and call the M.C. Miller sales team so that we may help you find the proper version for your needs.

Add the following application: (More info)

How many survey crews are you outfitting?

Data Probe and Electrode Options

Do you require Fixed Electrode data-probes or Detachable Electrode data-probes?

"Fixed Electrode" Data-Probes are assembled with non-detachable RE-5C type reference electrodes, while the "Detachable Electrode" Data-Probes incorporate a universal adapter that allows the attachment of various electrode types to the units, including the RE-5C, the RE-7 and the IonX Calibrated RE-5C electrode types.


What will be the polarity of the CIS readings?

Wire and Dispenser Options

How do you plan to dispense the trail wire?

When a wire measurer and a counter/audible display unit are used in conjunction with a trail wire dispenser system, an audible signal is generated every 2.5 feet (or every meter, in the case of the metric system) and the operator triggers readings in response to the audible signal. Alternatively, readings can be triggered automatically via a trigger cable. Automatic triggering is not possible for Combined DCVG/CIS surveys, as in this case the DCVG voltage is recorded first (at each measurement location) and the CIS voltage recordings are triggered internally by the data-logger itself.

In the absence of a wire measurer/counter system, periodic stationing correction can be achieved via the Gx data-logger software at survey flags or known stations, such as test points having known station numbers.


What gauge of trail wire do you require?

How many trail wire spools do you require?

Switchbox options

Will you collect both DCVG and CIS data on a single pass down the pipeline?

Both DCVG and CIS data can be collected at each measurement location on a single pass with the addition of M. C. Miller's "Switch Box Controller", which automatically switches the reading configuration from "cell-to-cell" to "pipe-to-soil" at each measurement location. Although a single pass down the line is convenient, the process requires a time period at each measurement location corresponding to several current interruption cycles.

If you answer "Yes" to the above question, a Switch Box Controller will be included in your package. A "No" response will indicate that you plan to perform separate DCVG and CIS surveys and, therefore, a Switch Box Controller will not be necessary. Note: Separately-performed surveys are also possible in the case of a package that includes a Switch Box Controller, as appropriate cables (and dual-probe adapter) are provided in either case.

PC Software





PC software is required to download and manipulate survey data from our data-loggers.
You are required to use one of our ProActive programs or our MCM_ESD program.

The MCM_ESD program is supplied “free-of-charge” with the data-logger, however only allows the CIS and DCVG survey data to be downloaded from the data-logger and exported to Excel.

We have recently released a new interation of our Pipeline Integrity system, ProActive Pro. Record, report and manage your data with the latest in Corrosion Protection Data Managment Software.
Click here to learn more.

How many ProActive licenses do you require?
rev MCM.06.17.21.1